Features :
International market: CLIA has been put into operation in 1980s, which is widely used in clinical application. It is in the maturity state at present, its margin and growth rate are much higher and the system have the following features:
- Reaction principle: Enzyme chemiluminescence or direct chemiluminescence
- Marker: Enzyme or luminescence material
- Solid carrier: Microplate, magnetic particles, reaction cuvette
- Measuring procession: Adding sample, incubation, lavaging, adding Luminescence liquid
- Measuring precision: Quantitative
- Testing items: Wide range
- Radiation: None
- CV: 3%
- Calibration: 2 points calibration, cost-effective
Test Parameters :
Reproductive Endocrinology
- FSH
- Estradiol 2
- LH
- Prolactin
- Progesterone
- Testosterone
- HCG
- ASA
- ACA
- AEA
- AOA
- ATB
- ZP
- HCG-Ab
Tumor Markers
- AFP
- CEA
- Ferritin
- PSA
- FPSA
- CA15-3
- CA125
- CA19-9
- CA50
- NSE
Thyroid Hormones
- Total T3
- Total T4
- Free T3
- Free T4
- TSH
Diabetes
- C-Peptide
- Insulin
- Anti-Insulin
Infectious Disease
- HBsAg
- HBsAb
- HBeAg
- HBeAb
- HBcAb
Torch
Specification :
- Throughput: 120 test/hour
- Reagent position: 24, place 24 kinds of reagents at the same time
- Reagent-frozen function: optional
- One-time loading volume of reaction cuvette and sample tube: 180
- Continuous loading sample and reaction cuvette: available
- Reagent bar code: available
- Reagent remainder warning: available
- Automatic dilution: available
- Solid phase: coated microplate/tube
- Luminescent pattern: enzymic chemiluminescence
- Calibration pattern: Two or whole point, put calibration serum at the sample position
- Incubation temperature: 37±1C
- Sample volume: 10150 ul
- Working pattern: batch handling, emergency
- System initiation time: < 15 minuets
- Ambient temperature: 18 C -30 C
- Humidity: 20%-80%
- Power source: 110V/220v±10 50Hz±1Hz
Performance characteristics :
- Pipeline system
- Bar code scanning
- Reagent Recognition
- Liquid-level detection
- Insert emergency randomly
- Quality control management
Sample incubation module :
- 37 C constant-temperature environment, plus vibratory mixing at the same time to Guarantees the uniformity of the response and the rapidity
Waste handling module :
- Handling solid-phase and liquid waste separately, conforms to the environmental protection standard and the stipulation of processing dumps pollutants of the hospital
Fluid supply module :
- Can store up common reagents which the instrument needs and also do automatic control, monitor, prompt renewal reagent stock
Photon count module :
- Using PMT single photon enhanced single photon counting
The main parts of the instrument
Handling module :
- Sample and reaction cuvette position: 180 positions, either sample tube or reaction cuvette can be settled
- Bar code reading: laser bar code reader can read original tube and reaction cuvette bar code
- Sample replacement: sample can be increased and replaced at anytime
- Emergency sample positions: 10
eagent area :
- Reagent position: 24
- Reagent replacement: reagent can be replaced, increased or reduced at anytime
- Reagent shift: all reagents and positions can be shifted
- Reagent bar code reading: Laser bar code reader
- Reagent mixing: Automatically carries on when it is used in the machine or after a period of time
- Reagent pre-handling: non
- Reagent warm-up: non
Aspiration unit :
- Liquid-level induction: available
- Aspiration process: perform corresponding aspiration program as per different reagent instructed by software
System Control Operators Module :
- Computer: Brand Computer
- Input method: The keyboard, the mouse, bar code scanner of Grasps
- Display device: screen 15" monitor
- Output way: Laser printer, RS232 output terminal
- Stock examination: Sample monitor, reagent monitor, using up monitor
- Computation of the sample quantity: Automatic
- The prompt of wrong and reports to the police: Man-machine dialogue form
- Maintenance operation: Automatic vegetable unitary direction operation