Patient Monitor System

MM-C003 Patient Monitor

Product Description

Features :

  • Standard parameter: ECG,RESP,NIBP, SPO2, TEMP, PR
  • 12.1 large-screen color TFT display
  • Built in high capacity battery, up to 4 hours working tine
  • 7- lead ECG waveforms display , big fonts observational interface
  • Reviewable ECG waveforms, maximum 240 hours reviewing graphic trends
  • Digital SPO2 technique, precise measurement for weal perfusion and finger shaking
  • Arrhythmia and S-T segment analysis and pacemaker detection
  • Protection against interference from defibrillation and electrosurgical unit
  • Applicable to ICU, CCU, operation, adult, pediatric and neonatal patients

Specification :

  • ECG
  • Full lead: I, II, III, AVL, AVR, AVF and V
  • Gain 5mm/mV, 10mm/mV, 15mm/mV, 20mm/mV and 25mm/mV
  • Scanning speed: Changeable with three grades of 12.5mm/s, 25mm/s and 50mm/s
  • Band width :0.05Hz-100Hz(3dB)
  • Heart rate:
  • Scope: 15 times/minute to 300 times/minutes
  • Accuracy: ±1 time/minute
  • Variation of heart beat LORENZE drawing: Analysis on heart beat data for the current 5 minutes with histogram during RR period.
  • Arrhythmia :Twenty kinds of common abnormal ECG can be analyzed, with ECG data of 1000 times of arrhythmia kept and with 10 seconds kept for each time.
  • Accuracy: Error rate < 20%
  • Undetected rate < 20%
  • Analysis function should be started when using the above two kinds of function.
  • ST section
  • Scope: ±0.8mV
  • Precision : ±0.05mV


SpO2

  • Detection scope: 0%-100%
  • Accuracy : ±1% 90%-100% ±2% 70%-89%


NIBP

  • Theory Electric oscillator
  • Cuff gassing time less than 15 seconds
  • First-time gassing pressure: dynamic state 24kPa 180 mmHg
  • Manual selection: 9.3kPa 70 mmHg13.3kPa 100 mmHg16.0kPa 120 mmHg
  • 18.6kPa 140 mmHg20.0kPa 150 mmHg21.3kPa 160 mmHg
  • Automatic detection period: 1 minute to 240 minutes
  • Stop size1 min1 min -10min, 5min(10 min -30min), 10min(30 min -90min) and 30min90 min -240min
  • Detection scope:
  • Systolic blood pressure: 4kPa -34kPa(30mmHg -255mmHg)
  • Diastolic pressure: 2kPa -29.3kPa(15mmHg -220mmHg)
  • Mean pressure : 2.7kPa31.3kPa 20mmHg235mmHg
  • Detection accuracy
  • Static pressure: ±3mmHg
  • Pulse rate: ±2%


Resp

  • Chest impedance method or concentration of carbon dioxide at end of respiration
  • Scope of chest impedance method 0 time/minute – 100 minutes/minute
  • Precision of chest impedance method 1 time/minute
  • Detection scope of carbon oxygen at end of respiration 3mmHg-75mmHg 0.4%vol-9.9%vol
  • Detection scope of respiration rate: 2 times/minute ->60 times/minute including baby
  • Detection precision of respiration rate: ±1 time/minute
  • Temp
  • Single/double path
  • Type : Vascular/surface temperature
  • Scope: 20C50C
  • Accuracy : ±0.2 C


Invasive blood pressure (selected mating)

  • Single/double path
  • Type: direct and continuous detection
  • Scope: -6.67kPa(-50mmHg)—46.67kPa(350mmHg)
  • Precision: below 13.33kPa(100mmHg) ±0.27kPa(2mmHg) 13.33kPa(100mmHg) above ±2%
  • Frequency responseDC-12Hz
  • Input resistance: not less than 500kΩ
  • Sensitivity of sensor: 5μV/V/mmHg
  • Motivation voltage5V (DC)
  • Accuracy of sensor: ±2
  • Isolation voltage: 4 kV

Invasive blood pressure (selected mating)

  • Single/double path
  • Type: direct and continuous detection
  • Scope: -6.67kPa(-50mmHg)—46.67kPa(350mmHg)
  • Precision: below 13.33kPa(100mmHg) ±0.27kPa(2mmHg) 13.33kPa(100mmHg) above ±2%
  • Frequency response:DC-12Hz
  • Input resistance: not less than 500kΩ
  • Sensitivity of sensor: 5μV/V/mmHg
  • Motivation voltage 5V (DC)
  • Accuracy of sensor: ±2
  • Isolation voltage: 4 kV