Features :

  • 6 Standard parameters: ECG, RESP, NIBP, SPO2, 2-TEMP, PR/HR, ETCO2, 2IBP and Recorder, AG, BIS, CO, OB/GYN (TOCO,FHR, FM) are optional
  • Patient range: Neonate, Pediatric, and adult patients
  • Touch Screen 15"high resolution 1024 X 768 color TFT LCD display
  • Real time S-T segment analysis (15 types), drug calculation (15 types), pace-maker detection.
  • Indication of Incorrect manipulation and malfunction analysis.
  • Patient info input management function
  • Multi-lead ECG waveforms display in phase.
  • Large volume of tabular and graphic trends information easy to recall.
  • Capture dynamic waveforms.
  • Efficient resistance to interference of defibrillator and HF knife.
  • UP to 6 hours working capacity of built-in rechargeable 2 battery.


Performance Specifications :

Display :

  • 15"color TFT Touch Screen
  • Rolling and refreshing waveform display
  • Resolution: 1024x768
  • Standard display
  • Multi channels display


Trace :

  • 6 waveforms
  • Sweep speed: 12.5mm/s, 25mm/s, 50mm/s


Indicator :

  • Power/battery indicator light
  • QRS beep and alarm sound


Battery :

  • Rechargeable lead acid cell, 12V/4AH
  • Max.24 hours for charging, 3 hours for continuous working


Trend time :

  • Above 256 hours

Alarm :

  • User-adjustable High , Medium and Low limits 3-level Audible and visual alarm


Recorder :

  • Built-in , thermal array
  • Plethysmogram waveform: 2 channels
  • Record mode: manual, on alarm, time-defined
  • Recording width: 50mm
  • Printing speed: 25mm/s
  • Recording type: Frozen waveform record
  • NIBP recall record
  • Trend table recordAlarm record
  • Fixed- time record


ECG :

  • Lead mode: 5 –leads (R,L,F,N,C)
  • lead selection: I,II,III,avR,avL,avF,V
  • Waveform: 2 and 6 channel selectable
  • Gain selection: 0.25mm/mv, 0.5mm/mv, 1 mm/mv, 2 mm/mv
  • Sweep speed: 12.5mm/s;25mm/s;50mm/s
  • Heart Rate range: Adult: 15~300bpm;Neonate:/Pediatric: 15~350bpm
  • Accuracy: ±1bpm or ±1%, whichever is greater
  • Resolution: 1bpm
  • Filter: Surgery mode :1~20Hz
  • Monitor mode: 0.5~40Hz
  • Diagnostic mode:0.05~130Hz
  • Scaling signal: 1mV, ±3%
  • Protection: Withstand 4000VAC/50 voltage isolation
  • Against electrosurgical interference and defibrillation
  • Alarm range: 15~350bpm
  • S-T segment detection: Measurement range:-2.0mV~ +2.0mV
  • Alarm Range: -2.0mV~ +2.0mV
  • Accuracy: -0.8mV ~+0.8mV
  • Error: ±0.02mV
  • Arrhythmia analysis: Yes. 15types


NIBP :

  • Method: Digital Automatic oscillometric
  • Operation mode: Manual/Automatic/Continuous
  • Auto measurement time: Adjustable(1~480min)
  • Measurement Unit: mmHg/Kpa selectable
  • Measurement types: Systolic, Diastolic, Mean
  • Measurement range:
  • Range of Systolic pressure: Adult: 40~270mmHg
  • Pediatric:40~200mmHg
  • Neonate: 40~135mmHg
  • Range of mean pressure: Adult: 20~235mmHg
  • Pediatric:20~165mmHg
  • Neonate: 20~110mmHg
  • Range of diastolic pressure: Adult: 10~215mmHg
  • Pediatric:10~150mmHg
  • Neonate: 10~100mmHg
  • Over-pressure protection: Double safety
  • Protection Resolution: 1mm Hg
  • Alarm: Systolic, Diastolic, Mean


SPO2 :

  • Measurement range: 0~100%
  • Resolution: 1%
  • Accuracy: ±2%(70-100%);0-69% unspecified
  • Alarm range: 0~100%
  • Pulse Rate: Range: 20~300bpm
  • Solution: 1bpm
  • Error: ±1bpm or ±2%, whichever is greater


RESPIRATION :

  • Method: Thoracic impedance
  • Measurement range: Adult : 7~120rpm; Neonate/Pediatric: 7~150rpm
  • Apnea alarm: YES, 10~40s
  • Solution : 1rpm
  • Accuracy: ±2rpm


Temperature :

  • Compatible probe: YSI or CYF
  • Measurement Range: 0~50 C
  • Resolution: 0.1 C
  • Accuracy: ±0.1 C
  • Channel: dual-channel, provide T1;T2,DT
  • Refreshing time: about 1s
  • Average measuring time: < 10s


IBP :

  • Measurement range: -10~300mmHg
  • Pressure name: ART,PA,CVP,RAP,LAP,ICP,P1,P2
  • Channel: 2 channels
  • Pressure transducer: sensitivity:5μV/VmmHg
  • Impedance range: 300-3000Ω
  • Accuracy: ±1mmHg or ±2%,whichever is greater(exclusive or transducer)
  • Alarm Range: -10~300mmHg


EtCO2 :

  • Measurement range: 0-99mmHg
  • Accuracy: ±2mmHg(0~40mmHg)
  • Sampling Range: 100ml/min
  • Sampling rate accuracy: 15%
  • Respiration rate: 0~120rpm
  • Respiration accuracy: ±2rpm(0~70rmp) ±5rpm(>70rmp)
  • Respiration time: < 240msec (10% to 90%)
  • Delay time: < 2s


Standard Configuration :

  • ECG
  • Heart Rate
  • Pulse Rate
  • NIBP
  • RESP
  • Temp
  • SPO2
  • Printer


Optional : Thermal Recorder, 2-IBP, EtCO2 (side stream or main stream)



Safety

  • IEC60601-1 approved, Category I BF, CF Type


Dimension and Weight

  • Dimension 325mm x 400mmx 188mm
  • Weight (with 2 batteries): < 7.0KGS


Operation Environment

  • Temperature: Working 0~+50ºC
  • Transportation and storage –20~+60ºC
  • Humidity: Working ≤85%
  • Transportation and storage ≤93%
  • Power: AC100-240V,50/60Hz