Product Description

We are regarded as one of the chief Electronic Cardiac Pacemaker Exporters in International market. We present a qualitative range of External Cardiac Pacemaker that is designed to for implantation permanently in the body. Cardiac Pacemaker is a battery powered device that monitors electrical pulses in heart when required. It also delivers electrical stimuli that make the heart beat contract in normal rhythm. We provide availability of External Cardiac Pacemaker in different specifications as per the requirements of customers.

Features :

  • The MM-CPM001 type is a Dual-Chamber Implantable Telemetering Electric Pacemaker is intended for treatment of atrioventricular heart blocks at Morgagni-Stokes syndrome and other cardiac rhythm disorders by electric stimulation of ventricles or auricles.
  • Adopts unipolar or bipolar electrodes with IS-1 standard tips (3.2 mm).
  • Programmable by means of UNI programmers.
  • The Pacemaker implements an automatic switch of stimulation mode with constant analysis of activity within refractory periods, measurement of electrodes' impedance, extensive statistics of the events' array displayed as convenient histograms and protection against pacemaker-mediated tachycardias.
  • Universal programmer (optional)


Telemetering information :

  • Model and serial number
  • Programmable parameters of stimulation
  • Battery condition
  • Impedance of electrode


Statistics :

  • imposed events via A and V channels
  • perceived events via A and V channels
  • combination of imposed/perceived events
  • quantity of changeovers in stimulation mode


Operation modes :

  • Stimulation modes: DDD, DDI, DОО, VDD, AОО, AAI, AAT, VОО, VVT
  • Stimulation frequency, imp./min: 30…70…120 (5 imp./min steps)
  • Amplitude of stimulating pulses, B (A and V): 0.80; 1.50; 2.20; 3.00; 3.90; 4.60; 5.40; 6.30
  • Duration of stimulating pulses, ms (A and V): 122…366…976 (122 ms steps)
  • A-channel threshold of sensitivity, mV: 0.5; 1.0; 1.5; 2.0; 2.5; 3.0; 3.5; 4.0
  • V-channel threshold of sensitivity: 1.0; 2.0; 3.0; 4.0; 5.0; 6.0; 7.0; 8.0
  • A-channel refractory period, ms: 200…300…500 (20 ms steps)
  • V-channel refractory period, ms: 200…260…500 (20 ms steps)
  • A-V delay: 100…180…300 (10 ms steps)
  • Frequency-dependent A-V delay: Off, short, medium, long
  • A-V delay control: 0 or -30 ms
  • Maximum frequency of synchronization: 60…140…180 imp./min (5 imp./min steps)
  • Blind period of auricles, ms: 50…150…200 (50 ms steps)
  • Input-output operation mode: UNI (unipolar) BIP (bipolar)
  • Automatic switchover of operation modes: On, Off
  • Programming of VARIO mode: by amplitude and duration


Specifications :

  • Overall dimensions: 52 х 47 х 9.5 mm
  • Weight: 24g
  • Type of electrode connector: IS-1 BI (3.2 mm)
  • Service life in STANDARD mode: not less than 7 years
  • Power source: lithium fluorocarbon cell 1.1 Ah