MRI Systems
MM-MRI002 Open MRI Systems
Product Description
MM-MRI002 Open MRI Systems
Specification :
Magnet System :
- You can choose any of the following magnet types: 0.2T, 0.3T, 0.35T, 0.4T, 0.5T open MRI systems)
- Open Permanent magnet, eddy current free & self-temperature control
- Self-temperature control system
- Shell
- Locating system
Magnet System :
- type: Permanent magnet, eddy current free, open C type & self-temperature control
- Field homogeneity: < ±2ppm(FWHH)/20cm DSV < 5ppm(VRMS)/40cm DSV
- Active shim: < ±1ppm(FWHH)/20cm spherical surface DSV < ±2ppm(VRMS)/40cm spherical surface DSV
- Vertical gap distance: 40cm
Image specifications :
Image types: T1 weighted image, T2 weighted image, T2* weighted image, PD weighted image, diffusion weighted image, fat suppressed image, water suppressed image, Magnetic resonance hygrography (MRCP MRM MRU), MRA Field of view: 40mm-400mm Acquisition matrix: 64x64-512x512 Graphics matrix max.: 1024x1024 Body in 30cm FOV: 1.5mm Head in 24cm FOV: 1mm
Orientation :
Slice orientation: transverse, sagittal, coronal, free oblique, multi-slice & multi-range Slice gap: 0-20mm
Auto pre-scan function :
Auto RF correction, auto frequency lock, auto gain, auto coil identification, auto coil tuning, active shim
RF transmitting & receiving system :
- Type of transmitter & receiver: Digital
- Frequency range: DC-22MHZ
- Maximum receiver bandwidth: 1.25MHZ
- Pre-amplifier: gain 30dB
- Noise figure: 0.3dB
- RF amplifier: ≥6kw
Gradient system :
Amplifier :
- Field strength: single axis 15mT/m, effective 25.9mT/m
- Slew rate: single axis 50mT/m/ms, effective 86mT/m/ms
- Linearity: 40cm*40cm*38cm ellipsoid<5%
Receiving system :
Head, Body (big), Body (small), Neck, Knee, Shoulder, Wrist coil each
Gradient System :
- Type of transmitter & receiver: Digital
- Gradient amplifier
- X Y Z gradient coil
Patient System :
- Patient table
- Doctor-patient communication system
Computer System :
- DELL imaging workstation
- dual-core processor (≥ 2.8GHz), Graphics memory: 128MB, Memory: 2 GB, Hard driver: 160 GB, Removable storage: CD+RW, 21" TFT monitor with at least 1280x1024resolution
- Console table
Software Package :
- The MRI system software, including: Field homogeneity package, Basic imaging sequence package, system controlling package, Data processing package, Image reconstruction package, image processing and analysis package, Self-default analysis package, Hydrography image package, Angiography image package, Diffusion image package and Laser camera communication package (DICOM 3.0)
Pulse sequence :
- Spin echo (SE)
- Multi-slice & Multi-echo (MSME)
- Fast Spin Echo (FSE)
- Single shot fast spin echo (SSFSE)
- Multi shot fast spin echo (MSFSE)
- Inversion recovery (IR)
- Short inversion tau IR (STIR)
- Fluid attenuated IR (FLAIR): T1W, T2W
- Inversion recovery fast spin echo (IRFSE)
- Gradient echo (GRE): 2D/3D
- Steady state process GRE (SSPGRE)
- MRA: TOF 2D/3D
- Echo Planar Imaging (EPI)
Image display & post processing :
- Image post processing: filter, zoom, cut, text illustration & elimination, image offset, auto adjustment of window length & width
- Image analysis: interested area illustration, distance measurement
Accessories :
- Mattress, Pillows, testing samples, warning signs
Option systems :
- 0.2T
- 0.3T
- 0.35T
- 0.4T
- 0.5T
Coils :
- Head, Body (big), Body (small), Neck, Knee, Shoulder, Wrist coil each, …etc
|