MRI Systems

MM-MRI002 Open MRI Systems

Product Description

MM-MRI002 Open MRI Systems

Specification :

Magnet System :

  • You can choose any of the following magnet types: 0.2T, 0.3T, 0.35T, 0.4T, 0.5T open MRI systems)
  • Open Permanent magnet, eddy current free & self-temperature control
  • Self-temperature control system
  • Shell
  • Locating system


Magnet System :

  • type: Permanent magnet, eddy current free, open C type & self-temperature control
  • Field homogeneity: < ±2ppm(FWHH)/20cm DSV < 5ppm(VRMS)/40cm DSV
  • Active shim: < ±1ppm(FWHH)/20cm spherical surface DSV < ±2ppm(VRMS)/40cm spherical surface DSV
  • Vertical gap distance: 40cm


Image specifications :

Image types: T1 weighted image, T2 weighted image, T2* weighted image, PD weighted image, diffusion weighted image, fat suppressed image, water suppressed image, Magnetic resonance hygrography (MRCP MRM MRU), MRA Field of view: 40mm-400mm Acquisition matrix: 64x64-512x512 Graphics matrix max.: 1024x1024 Body in 30cm FOV: 1.5mm Head in 24cm FOV: 1mm

Orientation :

Slice orientation: transverse, sagittal, coronal, free oblique, multi-slice & multi-range Slice gap: 0-20mm

Auto pre-scan function :

Auto RF correction, auto frequency lock, auto gain, auto coil identification, auto coil tuning, active shim

RF transmitting & receiving system :

  • Type of transmitter & receiver: Digital
  • Frequency range: DC-22MHZ
  • Maximum receiver bandwidth: 1.25MHZ
  • Pre-amplifier: gain 30dB
  • Noise figure: 0.3dB
  • RF amplifier: ≥6kw


Gradient system :

Amplifier :

  • Field strength: single axis 15mT/m, effective 25.9mT/m
  • Slew rate: single axis 50mT/m/ms, effective 86mT/m/ms
  • Linearity: 40cm*40cm*38cm ellipsoid<5%


Receiving system :

Head, Body (big), Body (small), Neck, Knee, Shoulder, Wrist coil each

Gradient System :

  • Type of transmitter & receiver: Digital
  • Gradient amplifier
  • X Y Z gradient coil


Patient System :

  • Patient table
  • Doctor-patient communication system


Computer System :

  • DELL imaging workstation
  • dual-core processor (≥ 2.8GHz), Graphics memory: 128MB, Memory: 2 GB, Hard driver: 160 GB, Removable storage: CD+RW, 21" TFT monitor with at least 1280x1024resolution
  • Console table


Software Package :

  • The MRI system software, including: Field homogeneity package, Basic imaging sequence package, system controlling package, Data processing package, Image reconstruction package, image processing and analysis package, Self-default analysis package, Hydrography image package, Angiography image package, Diffusion image package and Laser camera communication package (DICOM 3.0)


Pulse sequence :

  • Spin echo (SE)
  • Multi-slice & Multi-echo (MSME)
  • Fast Spin Echo (FSE)
  • Single shot fast spin echo (SSFSE)
  • Multi shot fast spin echo (MSFSE)
  • Inversion recovery (IR)
  • Short inversion tau IR (STIR)
  • Fluid attenuated IR (FLAIR): T1W, T2W
  • Inversion recovery fast spin echo (IRFSE)
  • Gradient echo (GRE): 2D/3D
  • Steady state process GRE (SSPGRE)
  • MRA: TOF 2D/3D
  • Echo Planar Imaging (EPI)


Image display & post processing :

  • Image post processing: filter, zoom, cut, text illustration & elimination, image offset, auto adjustment of window length & width
  • Image analysis: interested area illustration, distance measurement


Accessories :

  • Mattress, Pillows, testing samples, warning signs


Option systems :

  • 0.2T
  • 0.3T
  • 0.35T
  • 0.4T
  • 0.5T


Coils :

  • Head, Body (big), Body (small), Neck, Knee, Shoulder, Wrist coil each, …etc