Syringe Infusion Pump

MM-SIP003 Automatic Double Channels Syringe Pump

Product Description

Features:

  • Multi-channels (Double-channels), sub-rate injection
  • Four kinds of injection modes: Rate mode, Time mode, Body Weight mode,link mode.
  • Innovative design of outer appearance gives a strong sense of science and technology
  • Double CPU makes the process of injection safer and more reliable.
  • Brand-new STM32 ARM-Cortex M3 plat-form, optimized circuit design, operation rate more faster and stable
  • The use of TFT color LCD makes the screen display more remarkable.
  • Digital menu, easy operation; functions fully meet the clinical demand.
  • Ample and user-friendly indicator information; accurate and complete alarm information to ensure safe injection.
  • Aluminum alloy base, integrative pump device makes more smooth operation and easier installation and maintenance.


Specifications


Maximum injection rate : 1500 ml/h (Different syringes have different maximum flow rate.)
Injection flow rate range : 5 ml injector: 0.1.100ml/h 10 ml injector: 0.1.200 ml/h 20 ml injector: 0.1.400 ml/h 30 ml injector: 0.1.600 ml/h 50 ml injector: 0.1.1500 ml/h
Injection increment : 0.1
Bolus rate : 5 ml injector: 100ml/h 10 ml injector: 200 ml/h 20 ml injector: 400 ml/h 30 ml injector: adjustable from 400.600 ml/h 50 ml injector: adjustable from 400.1500ml/h
Injection mode selection : 1. Rate mode; 2. Time mode; 3. Body Weight mode; 4. Link mode
Rate mode : Rate: 0.1.1500.0ml/h (maximum value depends on the injector specifications)
Time mode   Time: 1minute.2000 minutes. Volume limit: 0.1ml.999.9 ml
Body Weight mode   Weight: 0.1.300.0 kg Drug: 0.1.999.9 mg Volume: 0.1.999.9 ml Dose: 0.1.9999.9 (restricted to unit, drug, solution, weight and injector specification). Unit: mg/kg/h, ug/kg/min
KVO rate   Adjustable range: 0.5.0ml/h (begin the KVO function under the occlusion situation); Setting value as 0 to cancel the KVO function when it is unnecessary in use.
Water-proof grade   IPX1
Injection pressure   The maximum pressure is 300 kpa, occlusion alarm pressure gate value is 40kPa.160kPa, when pressure value is minimum, injection rate is 5ml/h, the longest alarm time is 10 minutes.
Preset volume scope   0.1.999.9 ml
Preset time scope   0.2000 minutes
Accumulated injection volume display   0.1.999.9 ml
Injection accuracy   ±5.
Power supply   100V-240V., 50Hz,±1Hz, 30VA
Battery   Rechargeable lithium polymer battery, 7.4V, 1600mAh
Maximum power consumption   10VA, running more than 2 hours at the rate of 5ml/h after being fully charged.
Battery charge   When double-channel syringe pump is connected to AC power and the power is on, the battery will charge automatically. (about 8.14 hours to recharge fully)
Fuses   T 2AL 250V
Displayed and indicated information   Injection rate, accumulated volume, syringe specification, battery capacity, bed No., AC power indicator, operation indication, etc.
State indication information   Stop, injection, bolus, KVO ( If KVO rate is set as 0, it doesn't display KVO when occlusion alarm occurs)
Alarm functions   Near completion, Over, occlusion, disengage, low battery, abnormal 1, abnormal 2, abnormal 3, abnormal 4, serious low battery
Size of the outer shell   320 mmx110 mmx200mm.(length x width x height)
Classification   Class, Type BF
Outer shell material   ABS Plastic
Operating condition   Environment temperature:.5.40, air pressure: (86.106) kPa, relative humidity: <80%
Storage condition   Environment temperature:.40.55, air pressure: (50.106) kPa, relative humidity: <95%. No poisonous gas and well ventilation
Applicable syringes   National standard syringes: 5ml, 10 ml, 20 ml, 30ml, 50 ml
Standards : GB9706.1-2007, GB 9706.27-2005, ISO7886-1:1993, GB9969.1-1998, GB/T14710.1993, GB191-2008, YY0466-2003