Syringe Infusion Pump
MM-SIP003 Automatic Double Channels Syringe Pump
Product Description
Features:
- Multi-channels (Double-channels), sub-rate injection
- Four kinds of injection modes: Rate mode, Time mode, Body Weight mode,link mode.
- Innovative design of outer appearance gives a strong sense of science and technology
- Double CPU makes the process of injection safer and more reliable.
- Brand-new STM32 ARM-Cortex M3 plat-form, optimized circuit design, operation rate more faster and stable
- The use of TFT color LCD makes the screen display more remarkable.
- Digital menu, easy operation; functions fully meet the clinical demand.
- Ample and user-friendly indicator information; accurate and complete alarm information to ensure safe injection.
- Aluminum alloy base, integrative pump device makes more smooth operation and easier installation and maintenance.
Specifications
Maximum injection rate |
: |
1500 ml/h (Different syringes have different maximum flow rate.) |
Injection flow rate range |
: |
5 ml injector: 0.1.100ml/h 10 ml injector: 0.1.200 ml/h 20 ml injector: 0.1.400 ml/h 30 ml injector: 0.1.600 ml/h 50 ml injector: 0.1.1500 ml/h |
Injection increment |
: |
0.1 |
Bolus rate |
: |
5 ml injector: 100ml/h 10 ml injector: 200 ml/h 20 ml injector: 400 ml/h 30 ml injector: adjustable from 400.600 ml/h 50 ml injector: adjustable from 400.1500ml/h |
Injection mode selection |
: |
1. Rate mode; 2. Time mode; 3. Body Weight mode; 4. Link mode |
Rate mode |
: |
Rate: 0.1.1500.0ml/h (maximum value depends on the injector specifications) |
Time mode |
|
Time: 1minute.2000 minutes. Volume limit: 0.1ml.999.9 ml |
Body Weight mode |
|
Weight: 0.1.300.0 kg Drug: 0.1.999.9 mg Volume: 0.1.999.9 ml Dose: 0.1.9999.9 (restricted to unit, drug, solution, weight and injector specification). Unit: mg/kg/h, ug/kg/min |
KVO rate |
|
Adjustable range: 0.5.0ml/h (begin the KVO function under the occlusion situation); Setting value as 0 to cancel the KVO function when it is unnecessary in use. |
Water-proof grade |
|
IPX1 |
Injection pressure |
|
The maximum pressure is 300 kpa, occlusion alarm pressure gate value is 40kPa.160kPa, when pressure value is minimum, injection rate is 5ml/h, the longest alarm time is 10 minutes. |
Preset volume scope |
|
0.1.999.9 ml |
Preset time scope |
|
0.2000 minutes |
Accumulated injection volume display |
|
0.1.999.9 ml |
Injection accuracy |
|
±5. |
Power supply |
|
100V-240V., 50Hz,±1Hz, 30VA |
Battery |
|
Rechargeable lithium polymer battery, 7.4V, 1600mAh |
Maximum power consumption |
|
10VA, running more than 2 hours at the rate of 5ml/h after being fully charged. |
Battery charge |
|
When double-channel syringe pump is connected to AC power and the power is on, the battery will charge automatically. (about 8.14 hours to recharge fully) |
Fuses |
|
T 2AL 250V |
Displayed and indicated information |
|
Injection rate, accumulated volume, syringe specification, battery capacity, bed No., AC power indicator, operation indication, etc. |
State indication information |
|
Stop, injection, bolus, KVO ( If KVO rate is set as 0, it doesn't display KVO when occlusion alarm occurs) |
Alarm functions |
|
Near completion, Over, occlusion, disengage, low battery, abnormal 1, abnormal 2, abnormal 3, abnormal 4, serious low battery |
Size of the outer shell |
|
320 mmx110 mmx200mm.(length x width x height) |
Classification |
|
Class, Type BF |
Outer shell material |
|
ABS Plastic |
Operating condition |
|
Environment temperature:.5.40, air pressure: (86.106) kPa, relative humidity: <80% |
Storage condition |
|
Environment temperature:.40.55, air pressure: (50.106) kPa, relative humidity: <95%. No poisonous gas and well ventilation |
Applicable syringes |
|
National standard syringes: 5ml, 10 ml, 20 ml, 30ml, 50 ml |
Standards |
: |
GB9706.1-2007, GB 9706.27-2005, ISO7886-1:1993, GB9969.1-1998, GB/T14710.1993, GB191-2008, YY0466-2003 |
|