Maximum injection rate |
: |
1500ml/h (Different injectors have different maximum rate.) |
Range of flow rate |
: |
5ml injector: 0.1-100ml/h 10ml injector: 0.1-200ml/h 20ml injector: 0.1-400ml/h 30ml injector: 0.1-600ml/h 50ml injector: 0.1-1500ml/h |
Injection increment |
: |
0.1ml/h |
Bolus rate |
: |
5ml injector: 100ml/h 10ml injector: 200ml/h 20ml injector: 400ml/h 30ml injector: 400-600ml/h 50ml injector: 400-1500ml/h |
Injection mode selection |
: |
1. Rate mode 2. Time mode 3. Body Weight mode |
Rate mode |
: |
Speed: 0.1-1500ml/h (maximum value depends on the injector specifications) |
Time mode |
: |
Time:1-2000 minutes Accumulated injection volume: 0.1-999.9ml |
Body Weight mode |
: |
Weight: 0.1-300.0kg Drug: 0.1-999.9(mg) Volume: 0.1-999.9ml Dose: 0.1-9999.9(restricted to unit, drug, solution, weight and injector specification). Unit: mg/kg/h, ug/kg/min |
KVO rate |
: |
Adjustable range: 0.1ml/h-5.0ml/h (begin the KVO function under the occlusion situation) ; pressing STOP key to cancel the KVO function when it is unnecessary in use. |
IP grade |
: |
IP21 |
Injection pressure |
: |
The maximum pressure is 0.3Mpa, Occlusion alarm pressure value is 40kPa-160kPa when pressure value is minimum, injection rate is 25ml/h, the longest alarm time is 10 minutes. When pressure value is minimum, injection rate is 5ml/h, the longest alarm time is 10 minutes. |
Preset volume |
: |
0.1ml-9999.9ml |
Preset time |
: |
0-99 hours, 0-59 minutes |
Accumulated injection volume |
: |
0.1ml-9999.9ml |
Accuracy |
: |
3% |
Power supply |
: |
AC 100-220V,50/60Hz |
Battery |
: |
Rechargeable lithium polymer battery, 7.4 V, 1600mAh. |
Maximum power consumption |
: |
25VA, running more than 2 hours at the rate of 25ml/h after being fully charged. |
Battery charge |
: |
When syringe pump is connected to AC power, the battery will automatically recharge. (about 8-14 hours to recharge fully.) |
Fuses |
: |
T2AL250V- |
Displayed information |
: |
Flow rate; accumulated injection volume; injector specification; battery capacity; bed No.; AC power indicator, operation indication, etc. |
State indication information |
: |
Stop, inject, bolus, KVO (stop flashing, the other indicators flash by turns.) |
Alarm information |
: |
near completion, Over, occlusion, low battery, abnormal 1 (communications failure), abnormal 2 (pump stuck), abnormal 3 (wrong parameter), volume limited alarm, no AC power |
Maximum size of the outer shell |
: |
288x130x122 mm ( lengthx width x height ) |
Maximum weight |
: |
<3.0kg |
Classification |
: |
ClassII, Type BF |
Shell material |
: |
ABS plastic |
Operating conditions |
: |
Environment temperature 5-40, air pressure 80kPa -106kPa,relative humidity 80% |
Storage conditions |
: |
Environment temperature -40-55, air pressure 50kPa -106kPa,relative humidity 95% |
Applicable syringes |
: |
5ml.10 ml.20 ml.30ml.50 ml syringes |
Electrical safety |
: |
In accordance with the stipulation of GB9706.1-1995 |
Applied standards |
: |
According to the stipulation of YZB/Yue 001-2008 |